CORCOM Series FFD DC Feedthrough Filters

FFD Series - DC Feed Through Filters



Series FFD Schematic:
Offer reliability and performance in direct current applications.
Designed to meet EN132400 safety requirements
Custom designs available where special packaging, mounting, terminations, or multiple lines are required
RoHS compliant

Rated Voltage (max):130 VDC
Rated Current: 10 to 200 amps
Test Voltage (two seconds): 2500 VDC
Capacitor Class (EN132400): Designed to meet Y4
Pulse Test (EN132400): 2500V Peak
   Insulation Resistance (within 1 minute)
For C <0.33µF:R> 15000MΩ
For C>0.33µF:RC(M(Ω*µF)>5000s
   Operating Ambient Temperature Range (@ rated current Ir)
10 to 100 Amps: -40°C to +60°C
200 Amps: -40°C to +50°C
Category Temperature Range: -40°C to +85°C
Climatic Category: 40/85/21
MTBF: Typically >5 million hours
Insulating Materials Flammability Rating:

UL 94V-0


Filter
ID
Current
Rating
(Amps)
Value
(nF)
Inductance
(nH)
DC
Resistance
(MΩ) Max.
Standard Performance
10FFD6-CA102 x 10706
16FFD6-CA162 x 10706
32FFD6-CA322 x 10706
63FFD6-HB632 x 100803
100FFD6-NC1002 x 40902
200FFD6-ND2002 x 4701201
High Performance
10FFD6-HE102 x 1001405
16FFD6-HE162 x 1001705
32FFD6-HE322 x 1001805
63FFD6-NH632 x 4702403
100FFD6-PK1002 x 10002402
200FFD6-RP2002 x 47003302
Extended Performance
All units are stud-mounted (see PDF for dimensions)

Corcom Home  Corcom FFC Main  FFA Series  FFD Series  AFC Series  DFC Series